Thermo-dryer With air temperature adjustment function IDHx

Series/CAD Air flow capacity m3/h (ANR) Outlet air temperature adjustment range Outlet air set
pressure range
Outlet air
temperature
stability
Temperature
control method
IDHx4 100 to 500 15 to 30℃ 0.15 to
0.85 MPa
±0.1 Heater operation
PID control
IDHx6 200 to 800
Features
  • Stable supply of temperature and pressure controlled dry clean air.

Possible to supply compressed air with the same conditions and quality regardless of the season.

  • Application example:

Supplying compressed air with constant conditions to air bearings mounted on the tool.

  • Built-in filter

Nominal filtration: 0.01μm(99.9% filtration efficiency)
Outlet oil mist concentration: Max. 0.01 mg/m3(ANR)
Outlet cleanliness: Particles of 0.3 μm or more: 3.5 particles/L (ANR) or less

  • Power supply available all over the world

Single-phase 100VAC, 200VAC, 230VAC (50/60 Hz)

 

Heatless Air Dryer ID

Series/CAD Outlet flow L/min (ANR) Inlet flow L/min (ANR)
ID 80 to 780 100 to 975
Features
  • Supply dry air with a low dew point below -30ºC.
  • Compact and lightweight without a heater or an electric control board.
  • Possible to check the outlet dew point with the indicator. (Selfregenerative style allows for easy maintenance.)

 

Membrane Air Dryer IDGxA

Series/CAD Outlet flow L/min (ANR) Standard dew point (ºC )
IDG30A, 50A 300, 500 -20
IDG30HA, 50HA 300, 500 -15
IDG30LA, 50LA 75, 110 -40
Features
  • Energy saving design
  • Running cost reduced by 31%. (compared with existing models)
  • Non-fluorocarbon
  • Power supply not required.
  • Compatible with low dew points

 

Membrane Air Dryer IDG

Series/CAD Outlet flow L/min (ANR) Standard dew point (ºC )
IDG1 to 100 10 to 1000 -20
IDG3H to 100H 25 to 1000 -15
IDG30L to 100L 75 to 300 -40
IDG60S to 100S 50 to 150 -60
Features
  • Non-freon
  • Power supply not required
  • Compatible with low dew points.
  • No vibration or heat discharge.
  • With a dew point indicator.

 

Moisture Control Tube IDK

Series/CAD O.D./I.D. (mm) Effective length (mm) Applicable fittings
IDK02 2/1.2 100
200
KQ2
KJ
IDK04 4/2.5
IDK06 6/4
Features
  • Prevents condensation in piping for small cylinders/air grippers.
  • Diffuses water vapor in the piping to the outside.
  • All you have to do is install the moisture control tube. Additional power supply and works are not necessary.